Grove City YMCA Early Education Center
Grove City YMCA Early Education Center is a certified child care center in Grove City, PA, with capacity for 229 children. It holds a Keystone STAR 4 rating. Since August 2021, Pennsylvania certification staff have inspected it 7 times and confirmed violations in 2 complaint investigations. The state cited 38 violations, 2 of them core-safety (supervision, staff ratios, discipline, background checks, child protection or safe sleep), most often for building & playground safety (17 of 38). 1 citation came in the last 12 months. Measured by topic-weighted citations per inspection, it is #4 of 19 centers in Mercer County and has more citations per inspection than 64% of Pennsylvania certified centers.
Inspection record
Every state visit
What inspectors cited most
Citations, newest first
Based on interview with staff, the boiler was not working, and therefore the heat was not turned on, resulting in the temperature in the building being 61 degrees F in the morning when the facility opened, which is below the required 65 degrees F.
The file for Staff #1 contained a State Police Clearance that was lacking the dissemination date, therefore making it a non valid clearance. The file for Staff #1 also contained two mandated reported trainings that were more than 60 months apart.
The walls in gym have metal sticking out near the bottom of the wall that could cause cuts or bruising if a child would walk into them.
On the two outside play spaces that the infant and toddlers use there were gravel pieces observed that were less than 1 inch.
In Room 1 there was an Albuterol Inhaler that had expired 6.30.25.
These two occasions, 10.8.24-11.8.24 and 12.6.24-1.15.25, there were more than 30 days in between testing of the smoke detection system.
The file for Child #2 contained an agreement form that was lacking the fee to be charged.
The file for Child #1 contained an emergency contact form that was lacking the enrolling parent's work phone number.
The file for Staff #2 contained Pediatric First Aid that was obtained more than 90 days after staff's start date.
The foam magnetic blocks in Room #10 had bite marks in them which can be a choking hazard.
Show 28 older citations
The refrigerator in Room #9 was lacking an operating thermometer to ensure the refrigerator is holding temperature at 45 degrees F.
Room #9 was lacking a posted emergency transportation plan.
The criminal history clearance on file for Facility Person #1 was incomplete and therefore invalid. The current child abuse clearance on file for Facility Person #2 was completed more than 60 months after the previous child abuse clearance.
The letter to the parents explaining the emergency plan did not include the accommodations or reference the annual emergency drill.
There was an area of damaged plaster on the wall in the Pre-K nap room behind the dramatic play area. There was peeling paint / damaged plaster on the wall behind a handwashing sink in Room 2. There were two small areas of peeling paint in Room 1 - one on the wall between the door and the chalkboard, and one on the wall by the door to the storage closet near a sink.
The health assessment on file for child #1 did not include a statement that age-appropriate screenings recommended by the American Academy of Pediatrics were conducted since the time of the previous health report required by this section.
Staff in the young toddler room were observed manually lifting a lid on a trash can to dispose of a soiled diaper after a diaper change rather than use the receptacle's hands-free mechanism.
The current health assessment on file for Facility Person #3 was completed more than 24 months after the previous health assessment on file.
There were no written nonfamily references on file for Facility Person #2.
The facility's emergency plan does not include a plan for continuity of operations in an emergency.
The letter provided to the parents explaining the emergency plan does not include the program's plan for a lockdown.
There was an exit door propped open, near the library. There was no screen door at this exit.
The current health assessment on file for child #4, an infant, was completed more than 6 months after the prior health assessment on file.
There was no documentation of a current flu vaccine (recommended annually by the ACIP) on file for children #1, #2, and #3.
According to staff statements and documentation in the classroom, there was a child in Room 10 whose diaper was changed at 8:15 am, and then next checked and changed again at 10:50 AM.
The initial health assessment on file for child #2 did not include a statement that the child is able to participate in child care and appears to be free from contagious or communicable disease.
Facility Persons #2, #3, #4, and #6 have not completed the following required pre-service training within 90 days of their date of hire (see IS code sheet): Acceptable Health and Safety training. Facility Person #1 completed the training more than 90 days after starting.
The current staff evaluations on file for Facility Persons #3, #5, and #6 were completed more than 12 moths after the previous evaluations.
Facility was operating with children in care while the indoor temperature at the facility was below 65 degrees Fahrenheit.
Construction debris including metal poles, carpet remnants, and boxes of plank flooring were present in a hallway used by children in care. The materials were stored on each side of the hallway limiting the space to move freely and causing the potential for tripping or material falling and potentially which could have resulted in blunt force injuries.
In the 2nd-4th grade room, in an area accessible to children in care, several A/V cables that were secured at both ends were observed. Said cables present a strangulation hazard.
A toilet in the women's restroom located in the hallway of the school age side of the building was observed to have one exposed, upwardly facing bolt at the base of the toilet. A toilet in the K-1st grade room was observed to have two exposed, upwardly facing bolts on each side of the base of the toilet. Each noted area of concern are accessible to children in care and pose a puncture and/or laceration hazard.
In the 2nd-4th grade room, several metal brackets securing the heating/cooling system that runs the length of the room were observed to have sharp edges. Additionally, metal brackets that will eventually serve to secure an LCD panel were observed to have sharp edges. Noted areas of concern are accessible to children in care and pose a laceration and/or puncture injury hazard.
In the 2nd-4th grade room, an approximately 4'x2' metal shelf was observed to have a sharply pointed protrusion along the edge of the bottom of the shelf. In the school age hallway women's restroom, an approximately 3'x2' freestanding wooden table was observed to have an exposed nail on the underside of the tabletop. In the K-1st grade room, an approximately 3' round wooden table was observed to have exposed bolts on the underside of the table where each of the four table legs attached to the tabletop. On the door to the girl's restroom on the toddler side of the building, the wooden trim around the vent towards the bottom of the door was broken on one of the four trim pieces leaving a jagged, splintering edge. In the PreK room, an approximately 4'x2' bulleting board framed in aluminum was observed to have a sharp edge at the lower left joint of the framing. All of the above noted areas of concern were observed in areas accessible to children in care, and each presented the risk of causing puncture and/or laceration injuries.
An approximately 12" in diameter hole was observed in the outside grassy play space in an area accessible to children in care that, if stepped in, could cause an bone or muscle injury.
Two restrooms that will be used by children in care located in the hallway each contained toilets that had exposed, protruding bolts near the toilet base that could cause puncture and/or laceration injury.
The full length glass panels of the egress of the library lacked visual identifiers to assist in preventing a child from inadvertently walking/running into the glass, which could result in a blunt force injury.
An approximately 2'x1' metal wire mesh shelf in the School Age 2nd-4th grade room was observed to have a broken wire with an exposed sharp edge that could result in puncture and/or laceration injury. Two exposed, protruding screws (head side out) were observed on the inside of an approximately 3' high wooden refrigerator used by children in care. Contact with said screws could cause laceration injury.
“Core safety” marks citations about supervision and staff ratios, discipline and caregiver conduct, background checks, child protection and safe sleep, the topics our score weights most. Pennsylvania’s records don’t grade violations by severity. “Follow-up” marks a violation re-cited at a follow-up visit, counted once. How scores work.
Complaint investigations and reported incidents
Pennsylvania’s search lists complaint investigations in which the state found at least one violation (“verified complaints”). It does not say what a complaint alleged, or whether every violation relates to it. Incident investigations look into something that happened at the center; self-reported violations are ones the center reported to the state itself.
About this center
Common questions
Has Grove City YMCA Early Education Center had any serious violations?
Pennsylvania cited 2 violations since 2021 on the topics Daycare Record treats as core safety (supervision, staff ratios, discipline, background checks, child protection or safe sleep). The most recent, on Aug 13, 2025 (background checks): “The file for Staff #1 contained a State Police Clearance that was lacking the dissemination date, therefore making it a non valid clearance. The file for Staff #1 also contained two mandated reported trainings that were…” Pennsylvania’s records don’t grade violations by severity; each citation is listed in full above.
Have there been complaints about Grove City YMCA Early Education Center?
Pennsylvania lists 2 complaint investigations since 2021 in which it found at least one violation; the violations are listed above. Its search shows these “verified complaints” but not what a complaint alleged, or whether every violation relates to it.
What is Grove City YMCA Early Education Center’s Keystone STARS rating?
STAR 4, effective Oct 27, 2025. Keystone STARS is Pennsylvania’s quality rating program for child care, from STAR 1 to STAR 4. It measures program quality, not inspection results, so read both.
How does Grove City YMCA Early Education Center compare with other daycares in Mercer County?
It is #4 of 19 centers in Mercer County by topic-weighted citations per inspection, and has more citations per inspection than 64% of Pennsylvania certified centers with enough inspection history to compare.
When was Grove City YMCA Early Education Center last inspected?
Oct 29, 2025 (allocated unannounced monitoring). No violations were cited during that visit.
Who runs Grove City YMCA Early Education Center?
The legal entity on its Pennsylvania certificate is YMCA Of Franklin And Grove City.
Certified centers nearby
109 Breckenridge St, Grove City · 0.4 mi away · 95 spots More citations than most Chrichelles Childcare LLC
565 Kelly Blvd, Slippery Rock · 6.5 mi away · 94 spots Among the most cited Slippery Rock Area Parks and Recreation
320 N Main St, Slippery Rock · 6.8 mi away · 57 spots Too few inspections to compare Childrens Aid Society of Mercer Co Child Care CTR
350 W Market St, Mercer · 9.0 mi away · 83 spots Among the most cited Chrichelles Childcare LLC
2694 Perry Hwy, Portersville · 11.9 mi away · 22 spots More citations than most A & N Little Bugs Daycare & Preschool LLC
126 Main St, West Sunbury · 15.0 mi away · 19 spots Among the most cited
Citations are quoted from Pennsylvania Department of Human Services inspection records (Office of Child Development and Early Learning, Bureau of Certification Services), including each finding and the center’s plan of correction. Rule numbers refer mostly to 55 Pa. Code Chapter 3270, the rules for child care centers; a few cite Chapter 20, which covers every certified facility. Pennsylvania’s records don’t grade violations by severity; the “core safety” label and the score are Daycare Record’s.
To check the state’s own record, search the center’s name on COMPASS Child Care Provider Search and open its inspection history. Data refreshed Oct 16, 2026.
Comparing centers? See how to choose a daycare: 30 questions to ask and a printable checklist.
Concerned about this center? See how to report a daycare: which state line to call, what to write down and what happens next.